Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices Owner’s Manual P/N 1503-065 REV C, 5/02 Copyright 2001 DoorKing, Inc. All rig
Page 10 1.2 Wiring The wiring of this device is an extremely important and integral part of the access control system. It is very important that prop
Page 11 1.3 Wiring Diagram 1 2 3 4 5 6 7 8MasterCodeElectricStrikeMagneticLockGateOperator12-24 VoltAC or DCPushto ExitElectric StrikeMagnetic LockPo
Page 12 1.4 Circuit Board Terminal Identification 1. Input Power: 12-24 Volt AC or 12-24 Volt DC NEGATIVE 2. Input Power: 12-24 Volt AC or 12-24
Page 13 1.5 Aiphone Intercom Station Connections These wire diagrams are provided for convenience only. For detailed wiring information on Aiphone p
Page 14
Page 15 Keep a record of the programmed codes by completing the table on page 17. 2.1 Master Code The Master Code is a four-digit number that is use
Page 16 2.5 Programming Five-digit Entry Codes 1. Press *9 and enter the four-digit master code (short beep). 2. Press 1* (beep) to enter the first
Page 17 When operating the 1503 digital keypad entry device, each time a keypad button is pressed, a .2 second tone confirms the key press. This tone
Page 2
Page 3 Use this manual with the following models 1503-080, 1503-081, 1503-082 and 1504-081 Digital Keypad Entry Devices with circuit board 1500-010,
Page 4
Page 5 Table of Contents IMPORTANT NOTICES...
Page 6 2.9 • Prior to starting the installation, become familiar with the instructions, illustrations and wiring diagrams in this manual. • Never
Page 7 1.1 Mounting Surface mount units can be mounted directly to a wall or pilaster, or they can be mounted using a gooseneck mounting post (p/n 12
Page 8 1#0*7 8 96543210.0 5.252.8756.1253.05.02.52.5.8751.251.31.875 DiaModel 1504 Surface Mount - Lighted
Page 9 Flush mount keypad consist of two parts, the keypad and the rough-in box. Mount the rough-in box and wiring first, and then install the keypad