Installation/Owner’s Manual
Model 9050
Model 9050
Model 9050
Copyright 2009 DoorKing, Inc. All rights reserved.
TM
Copyright 2011 DoorKing, Inc. All rights reserved.
Use this manual for circuit board 4702-010 Revision A or higher.
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
Vehicular Slide Gate Operator
UL 325 Compliant
Circuit Board
Serial Number
and Revision Letter:
WARNING
MOVING GATE CAN CAUSE
Op
e
ra
te
ga
te on
ly
when g
a
t
e
area is in si
g
h
t
a
n
d
fre
e
of
p
e
o
p
le
a
n
d
o
b
s
truction
s
.
D
o
n
ot
a
llo
w child
ren
to play
in ga
te
a
r
e
a
or ope
rate
g
a
te.
Do
n
o
t
s
ta
n
d
in g
ate
p
a
th or walk
throu
g
h
path w
h
ile
gate is moving
.
Re
ad
owne
r’s
man
u
a
l
a
nd
s
afety
instructions.
SERIOUS INJURY OR
DEATH
CLASS
CERTI
FIED TO
CAN/CSA C22.2 NO. 24
7
C
ONF
ORM
S TO
ANSI/UL-325
VEHI
CULAR GATE OPERATOR
HP
5
3382
MODEL
SERIAL
VOLTS
PHASE
AMPS
60
Hz
MAX GAT
E LOAD
DoorKing, Inc., I
n
gl
e
w
ood, CA
9050-065-M-3-11
Page view 0
1 2 3 4 5 6 ... 41 42

Summary of Contents

Page 1 - Model 9050

Installation/Owner’s ManualModel 9050Model 9050Model 9050Copyright 2009 DoorKing, Inc. All rights reserved.TMCopyright 2011 DoorKing, Inc. All rights

Page 2

9050-065-M-3-118Slide Gate Requirements The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with

Page 3 - SPECIFICATIONS

9050-065-M-3-119Slide Gate Protection ReverseLoopAutomaticExit LoopMinimizes the potential of the gate closing when a vehicle is present. Number and p

Page 4 - SECTION 3 - ADJUSTMENTS 20

9050-065-M-3-1110Gate End RetainerEnd Post SECTION 1 - INSTALLATION 1.2 Physical Stops for the Gate 1.1 Hardware for the Gate Good hardware is essent

Page 5 - TABLE OF CONTENTS

9050-065-M-3-11111.3 Typical Gate TypesThe Model 9050 operator is designed to be installed on these gate types. See the next 4 pages for specific oper

Page 6

9050-065-M-3-11121.4 Operator Mounting Positions• Operator’s chain idler wheels are factory set for the front position. • Remove only the top cha

Page 7 - Important Notices

9050-065-M-3-1113• Set one chain Idler wheel at the top and one in the center position on one side of the operator. • Remove both chain knockout

Page 8 - Classifications

9050-065-M-3-1114Note: Chain stops CANNOT be used for this installation. End post with a gate end retainer must be installed as the physical stop if

Page 9 - Glossary

9050-065-M-3-11151.5 Underground Conduit RequirementsSweepsConcretePadPrimary Operator Position Secondary Operator Position • Operator’s setup is the

Page 10 - Slide Gate Requirements

9050-065-M-3-11164” 11” Solenoid Lock Conduit Area 2.5” Electronic Box 1.6 Pad, Post or Ceiling Mount without/with J-Box SetupPost Mount with Condui

Page 11 - Slide Gate Protection

9050-065-M-3-11171.7 Mounting Operator and Chain1” minimum from operator housing to gate. Prior to mounting the operator, be sure that the correct cha

Page 13 - 1.3 Typical Gate Types

9050-065-M-3-1118Endless Idler Assembly (On Select Installations) 1.8 Installation of Warning SignsThis DoorKing Slide Gate Operator is shipped with

Page 14 - Top View

9050-065-M-3-11192.1 High Voltage Wire Runs2.2 High Voltage Terminal ConnectionIf power wiring is greater than the maximum distance shown, it is recom

Page 15

9050-065-M-3-1120L1NCNOSELFTESTTIMEDELAYREVSENSREVERSE LOOPEXIT LOOP1ON2 3 4 5 6 7 81211109876543219410L194103.1 4702 Circuit Board Description and A

Page 16 - Gate in Open Position

9050-065-M-3-11217-OFF7-OFF7-ON7-ON8-OFF8-ON8-OFF8-ONGate CloseBack-OffPositionGate OpenBack-OffPositionNormal Setting. Gate fully opens. Gate stops s

Page 17 - 9050-065-M-3-11

9050-065-M-3-11223.3 Automatic Open / Close Limit AdjustmentGate MUST open until it contacts the physical “open” stop. (if gate starts to close, turn

Page 18 - Pad Mount with Conduit

9050-065-M-3-1123Give open command to cycle the gate or momentarily jumper terminals 8 and 12 to open gate.While gate is cycling, slowly rotate revers

Page 19

9050-065-M-3-1124NCNOSELFTESTTIMEDELAYREVSENSREVERSE LOOPEXIT LOOP1ON2 3 4 5 6 7 81211109876543214702-010WARNINGMOVING GATE CAN CAUSEOperate gate onl

Page 20 - Endless Idler Assembly (

9050-065-M-3-1125NCNO4702-010121110987654321Gate FrameGate Frame5”or Lessor LessNon-Secure Side Outside PropertySecure Side Inside PropertyFiller Post

Page 21 - 2.1 High Voltage Wire Runs

9050-065-M-3-1126NCNO4702-010121110987654321NCNO4702-010121110987654321Wireless Reverse Edge Sample Setup - Single ReceiverPhoto Sensor and Wireless

Page 22 - SECTION 3 - ADJUSTMENTS

9050-065-M-3-1127Reverse4 Ft. min. to avoid gatemovement interference.4 Ft. min. to avoid gatemovement interference.4 Ft. min. to avoid reverseloop in

Page 23 - 3.2 DIP-Switch Settings

9050-065-M-3-111DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of Do

Page 24 - “Multiple Gate Cycles”

9050-065-M-3-1128DANGERHIGH VOLTAGE!5.1 Main Terminal DescriptionLow Voltage CommonDry Relay ContactEarth GroundCircuit Board PowerCircuit Board Powe

Page 25 - 3.4 Clutch Adjustment

9050-065-M-3-1129NCNO4702-0101211109876543215.2 Control Wiring for Single/Primary OperatorKey SwitchStand-AloneKeypadStand-AloneCard ReaderTelephoneEn

Page 26 - 4702-010

9050-065-M-3-1130NC NO 4702-010 12 11 1 2 3 45 6 10 9876 5 4 3 2 1 NC NNO UL 325 Terminal Open Photo Close Photo Open Edge NC NO 4702-010 12 11 1 2 3

Page 27 - 6-Pin UL 325 Terminal Wiring

9050-065-M-3-1131SECTION 6 - OPERATING INSTRUCTIONSWARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. N

Page 28 - (If necessary)

9050-065-M-3-11326.2 Shutdown ConditionsUnder various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. To deter

Page 29 - 4.3 Loop Detector Wiring

9050-065-M-3-11336.3 Manual Gate OperationFail-Safe Manual Release System (Factory Installed)This operator is equipped with one of two types of manual

Page 30 - 5.1 Main Terminal Description

9050-065-M-3-1134Key Release Emergency Vehicle Access Conditions Fail-Secure Manual Release System (Owner Installed)This manual release system (Insta

Page 31

9050-065-M-3-11357.1 MaintenanceSECTION 7 - MAINTENANCE AND TROUBLESHOOTINGInspection and service of this gate operator by a qualified technician shou

Page 32 - 3-Wire Receiver

9050-065-M-3-11367.2 TroubleshootingHave a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of checking up to 500 meg-ohms of

Page 33

9050-065-M-3-1137Symptom Possible Solution(s)• Check the input LEDs. Any ON will hold the gate open and indicates a problem with a keying device. •

Page 34 - 6.2 Shutdown Conditions

9050-065-M-3-112SPECIFICATIONS 1SECTION 1 - INSTALLATION 10SECTION 2 - AC POWER TO OPERATOR(S) 19ASTM 2200 Standard for Gate ConstructionImportant Sa

Page 35 - 6.3 Manual Gate Operation

9050-065-M-3-11387.3 Accessory ItemsThe following accessory items are available for the model 9050 slide gate operator.Contact Sensors - For use as a

Page 36 - Key Release

9050-065-M-3-1139Model 9050 1/2 HP 115 VACReset AC Power Alarm Blue Blue Blue Red Red Red White White BrownBrownBrown Brown Black Black White White Wh

Page 37 - Monthly Interval

Installation/Owner’s ManualModel 9050Model 9050Model 9050Copyright 2009 DoorKing, Inc. All rights reserved.Use this manual for circuit board 4702-010

Page 38 - Symptom Possible Solution(s)

9050-065-M-3-113SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION 244.1 UL325 terminal Description4.2 Secondary Entrapment Protection Device Locations4.3

Page 39

9050-065-M-3-114Instructions regarding intended installation: Vehicular gates should be constructed and installed in accordance with ASTM F2200; Stan

Page 40 - 7.3 Accessory Items

9050-065-M-3-115• For gate operators utilizing contact sensors: 1. One or more contact sensors shall be located where the risk of entrapment or obs

Page 41 - Model 9050 1/2 HP 115 VAC

9050-065-M-3-116UL 325 Entrapment ProtectionClass I Class I and IIClass IIIClass IVClass II Class III Class IV A vehicular gate operator (or system)

Page 42 - Installation/Owner’s Manual

9050-065-M-3-117Glossary GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage b

Comments to this Manuals