FAAC International, Inc.
303 Lexington Avenue
Cheyenne, WY 82007
www.faacusa.com
November, 2003
400 Operator And
455 D Control Panel
Installation Manual
CONTENTS
Important Safety Information 2
Technical Data 4
Unpacking the Operator 5
The 400 Compact Operator General Characteristics 6
Installation Instructions 6
Prepare the Gate 6
Manual Release Mechanism 7
Install the Operator 7
Install the 455 D Control Panel 10
Exploded View, 400 CBC 12
400 Parts List 13
The 455 D Control Panel General Description 14
Installing the 455 D Control Panel 14
Connect the Main Power Supply 14
Connect the Operator to the Control Panel 15
Check the Motor’s Direction of Rotation 15
Connect Other Devices 16
Set Other Operating Controls 18
Programming 20
Learning of Operating Times 22
Learning of Normal Times 22
Learning Times with Gatecoder 22
Automated Systems Test 23
Logic Tables of 455 D Control Panel 24
Maintenance 26
Safety in Gate Design 26
Troubleshooting 27
Limited Warranty 28
T HE 400 OPERATOR AND
455 D C
ONTROL PANEL:
I
NSTALLATION MANUAL
The 455 D Control Panel
Installation Instructions
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - CONTENTS

FAAC International, Inc. 303 Lexington Avenue Cheyenne, WY 82007 www.faacusa.com November, 2003 400 Operator And 455 D Control Panel Installation Ma

Page 2 - IMPORTANT SAFETY INFORMATION

Page 10 November, 2003 400 Operator And 455 D Control Panel Installation Manual 153682497351AABABCCDAFigure 7. The layout of a sample gate syste

Page 3 - U.L. CLASS AND FAAC OPERATOR

Page 11 November, 2003 400 Operator And 455 D Control Panel Installation Manual BLEED THE OPERATOR Air bubbles in hydraulic fluid cause erratic per

Page 4 - TECHNICAL DATA

Page 12 November, 2003 400 Operator And 455 D Control Panel Installation Manual EXPLODED VIEW, 400 CBAC

Page 5 - UNPACKING THE OPERATOR

400 PARTS LIST Page 13 November, 2003 400 Operator And 455 D Control Panel Installation Manual POS PART NO. DESCRIPTION QTY 1 2036 Galvanized N

Page 6 - INSTALLATION INSTRUCTIONS

THE 455 D CONTROL PANEL GENERAL DESCRIPTION The FAAC 455 D control panel is used to operate the following models. Swing gate operators: 400 412 4

Page 7 - TTACH THE MOUNTING HARDWARE

RADIO1-455D115 = 115V1-455D = 230VF2F1MMK+OP -CL+24 VFS WNC -B -STOPA + TXFS WW. L.LOCK9 10 11 12 13 14 15 16 17 18 1922 23 24 25LA MPCOMOP CLMOTOR 1M

Page 8 - THE OPERATOR

Page 16 November, 2003 400 Operator And 455 D Control Panel Installation Manual NOTE: In order to comply with UL 325, two setsof FAAC photobeams mus

Page 9

Page 17 November, 2003 400 Operator And 455 D Control Panel Installation Manual ACTIVATING DEVICES AND RADIO RECEIVER: The activating devices and r

Page 10 - 14 AWG B 4 × 14 AWG

• E (semi-automatic): This mode requires a command to open and a command to close. A second command during opening stops the gate. A second command

Page 11 - BLEED THE OPERATOR

Magnetic LockShadow LoopRev ersing Photocells(f or closing)3 & 4 Wire Radio Receiv ersN.C.N.O.COMN.C.N.O.COM1714182112 vacRelay+-Lock121978NCCCoil

Page 12 - EXPLODED VIEW, 400 CBAC

Both the installer and the owner and/or operator of this system need to read and understand this installation manual and the safety instructions suppl

Page 13 - 400 PARTS LIST

Page 20 November, 2003 400 Operator And 455 D Control Panel Installation Manual PROGRAMMING To program the automated system, the “Programming Mode”

Page 14 - THE 455 D CONTROL PANEL

Page 21 November, 2003 400 Operator And 455 D Control Panel Installation Manual ADVANCED PROGRAMMING + Display Function Default MAXIMUM TORQUE A

Page 15 - CONTROL PANEL

Page 22 November, 2003 400 Operator And 455 D Control Panel Installation Manual wired to terminals 9 and 14, or radio control): • When gate operat

Page 16 - CONNECT OTHER DEVICES

Page 23 November, 2003 400 Operator And 455 D Control Panel Installation Manual The procedure has ended and the gate is ready to operate, using defa

Page 17

Page 24 November, 2003 400 Operator And 455 D Control Panel Installation Manual THE 455 D CONTROL PANEL INSTALLATION INSTRUCTIONS A (Automatic) Logi

Page 18 - ET OTHER OPERATING CONTROLS

Page 25 November, 2003 400 Operator And 455 D Control Panel Installation Manual THE 455 D CONTROL PANEL INSTALLATION INSTRUCTIONS E (Semi-automatic)

Page 19 - 400 Operator And

THE 400 OPERATOR The FAAC recommended maintenance schedule varies according to the frequency of use of the operators, whether lightly used operators

Page 20 - PROGRAM BUTTONS

PROBLEM: THE GATE DOES NOT RESPOND TO AN ACTIVATING SIGNAL. SOLUTION: You should have at least one operator wired to terminals 1,2 and 3. Be sure th

Page 21 - ADVANCED PROGRAMMING

Page 28 November, 2003 400 Operator And 455 D Control Panel Installation Manual To the original purchaser only: FAAC International, Inc., warrants,

Page 22 - LEARNING OF NORMAL TIMES

November, 2003 400 Operator And 455 D Control Panel Installation Manual Model Duty Cycle Typical Use Class I: Residential Vehicular Gate Operator

Page 23 - AUTOMATED SYSTEM TEST

Page 4 November, 2003 400 Operator And 455 D Control Panel Installation Manual TECHNICAL DATA 400 Model Parameter Standard High Speed Slow Spee

Page 24 - S (Security) Logic (455 D)

Page 5 November, 2003 400 Operator And 455 D Control Panel Installation Manual UNPACKING THE OPERATOR When you receive your 400 Operator, complete t

Page 25

THE 400 OPERATOR GENERAL CHARACTERISTICS The FAAC 400 Operator is an automatic gate operator for a swinging gate leaf. It can accommodate a gate lea

Page 26 - MAINTENANCE

Page 7 November, 2003 400 Operator And 455 D Control Panel Installation Manual MANUAL RELEASE MECHANISM For installation of the locking cap cover s

Page 27 - TROUBLESHOOTING

Page 8 November, 2003 400 Operator And 455 D Control Panel Installation Manual Insert the rear fork (hex cut up if you have a nylon rear fork) into

Page 28 - LIMITED WARRANTY

Page 9 November, 2003 400 Operator And 455 D Control Panel Installation Manual Figure 5. Important mounting dimensions for outward swing 400 ope

Comments to this Manuals

No comments