This model is for use on vehicular
passage gates ONLY and not
intended for use on pedestrian
passage gates.
This model is intended for use in
Class I, II, III and IV vehicular slide
gate applications.
UL325
compliant
UL991
compliant
CSL24V
&
CSL24VH
VEHICULAR SLIDE GATE OPERATOR
INSTALLATION MANUAL
THIS PRODUCT IS TO BE
INSTALLED AND SERVICED BY
A TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
Visit www.liftmaster.com to
locate a professional installing
dealer in your area.
Your model may look different than the model illustrated in this manual.
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - INSTALLATION MANUAL

This model is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates. This model is intended for use in Class I,

Page 2

8This model is intended for use in vehicular slide gate applications:Gate Classifications: CLASS I, II, III, & IV Main AC Supply: 120 Vac or 240 V

Page 3 - TABLE OF CONTENTS

9FEATURES INTRODUCTIONFEATURESOPERATOR FEATURESCONTROL BOARD FEATURESEXPANSION BOARD FEATURES• Advanced "Centerpiece" Control Board• EMI A

Page 4 - UL325 MODEL CLASSIFICATIONS

10PREPARATIONGate must be constructed and installed according to ASTM F2200 standards (refer to page 4). Gate must fit specifications of operator (ref

Page 5

11SITE PREPARATIONVEHICLE LOOPSThe vehicle loops allow the gate to stay open when vehicles are obstructing the gate path. Suggested for vehicles 14 fe

Page 6 - GATE CONSTRUCTION INFORMATION

121 The gate operator should be installed near the front roller of the gate or near the back of the gate (in the OPEN position). The space between t

Page 7 - Property

13REAR INSTALLATION ONLY2312STANDARD INSTALLATION ONLYDO NOT run the operator until instructed.1 Manually open the gate and line up the front bracke

Page 8 - IMPORTANT SAFETY INFORMATION

14EARTH GROUND RODUse the proper earth ground rod for your local area. The ground wire must be a single, whole piece of wire. Never splice two wires f

Page 9

15POWER WIRINGWIRINGPOWER WIRINGThis operator can be wired for either 120 Vac or 240 Vac or a solar panel (not provided). Follow the directions accord

Page 10 - INTRODUCTION

16POWER WIRING CONTINUED...POWER WIRINGWIRINGSOLAR PANEL(S)1 Locate the red and black wires connected to the J15 plug labeled DC POWER on the contro

Page 11

17DUAL GATES ONLYDUAL GATES ONLYWIRINGOutsidePropertyInsideProperty!!COMMLINKB AOMN.C.COMMLINKB AOMN.C.2134Comm Link Data AComm Link Data BCom

Page 13

18DUAL GATES ONLYDUAL GATES ONLYWIRINGTurn on power to the operator.TO ACTIVATE THE WIRELESS FEATURE:1 Choose an operator to be the network primary

Page 14 - INSTALLATION

19DUAL GATES ONLY + CONNECT BATTERIESWIRINGDUAL GATES ONLYBIPART DELAY/SYNCHRONIZED CLOSEThe LOCK/BIPART DELAY switch is used only with dual gate appl

Page 15

20CONNECT BATTERIESWIRING33AH BATTERIESCONNECT BATTERIESThe batteries are charged in the circuit by the integrated transformer. The batteries are for

Page 16 - EARTH GROUND ROD

21OutsidePropertyInsideProperty!To reduce the risk of SEVERE INJURY or DEATH: • Without a properly installed safety reversal system, persons (partic

Page 17 - POWER WIRING

22OutsidePropertyInsideProperty!OutsidePropertyInsideProperty!23ALARMRESET1FINE TUNE THE FORCEThe FORCE DIAL on the control board is used for fine tun

Page 18 - POWER WIRING CONTINUED

23ERASE ALL CODES1 Press and release the LEARN RADIO button (operator will beep and green XMITTER LED will light).2 Press and hold the LEARN RADIO

Page 19 - DUAL GATES ONLY

24The basic installation is complete.INSTALL THE COVERFINISH INSTALLATIONINSTALL THE COVERTO INSTALL THE COVER1 Align the tabs on the rear cover wit

Page 20

25ABCDERESET SWITCHThe reset switch is located on the front of the operator and serves several functions.Toggling the reset switch will stop a moving

Page 21 - CONNECT BATTERIES

26CONTROL BOARD OVERVIEWADDITIONAL FEATURESCONTROL BOARD OVERVIEWSET OPEN Button The SET OPEN button sets the OPEN limit. See Adjust Limits section.SE

Page 22

27ACCESSORY FEATURES ON CONTROL BOARDADDITIONAL FEATURESACCESSORY FEATURES ON CONTROL BOARDAOpen Input (& common)(3-Button Control Station, 4 term

Page 23 - ADJUSTMENT

1SAFETY 1-7Safety Symbol and Signal Word Review . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1UL325 Model Classifications . . . . . .

Page 24

281SHADOW INTERRUPTEXITComSingle Button Control StationASBC3-Button Control StationBCComOpenCloseStopAUX Relay 2 N.C.ComAUX Relay 2 N.O.AUX Relay 1 N

Page 25 - PROGRAMMING

29ALARMRESET1SHADOW INTERRUPTEXITAux RelayN.C.COMN.O.Class 2 Power Source(32 V max, 5 A max)+—Warning LightAUX RELAY WIRING EXAMPLEACCESSORY FEATURES

Page 26 - FINISH INSTALLATION

30INITIAL LIMITS AND FORCE ADJUSTMENTFor dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the ope

Page 27 - OPERATION

31ADJUST THE LIMITSIf the limits have already been set the operator will exit the limit setting mode after resetting each limit.Set the Close Limit On

Page 28 - ADDITIONAL FEATURES

32GATE OPERATOR SETUP EXAMPLESADDITIONAL FEATURESGATE OPERATOR SETUP EXAMPLESThe following are example setups for the gate operator. Your specific sit

Page 29

33NOTES:• Severe or high cycle usage will require more frequent maintenance checks.• Limits may have to be reset after any major drive chain adjus

Page 30 - INTERRUPT

34The control board is equipped with many LEDs that have a variety of functions. The control board LEDs indicate the status of the operator, assist wi

Page 31

35INPUT LEDSOPEN INPUT OFF Input inactiveON Input activeBLINK Input active on other operatorCLOSE INPUT OFF Input inactiveON Input activeBLINK Input a

Page 32

36TROUBLESHOOTING CHARTTROUBLESHOOTINGFAULT POSSIBLE CAUSES CORRECTIONSOperator does not run and diagnostic LED not on.a) No power to control boardb)

Page 33

37TROUBLESHOOTING CHARTTROUBLESHOOTINGFAULT POSSIBLE CAUSES CORRECTIONSGate stops during travel and reverses immediately.a) Check DIAGNOSTIC LEDsb) In

Page 34

2CLASS I – RESIDENTIAL VEHICULAR GATE OPERATORA vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings,

Page 35 - MAINTENANCE

38TROUBLESHOOTING CHARTTROUBLESHOOTINGFAULT POSSIBLE CAUSES CORRECTIONSPhotoelectric sensor does not stop or reverse gate.a) Incorrect photoelectric s

Page 36 - TROUBLESHOOTING

39TROUBLESHOOTING CHARTTROUBLESHOOTINGFAULT POSSIBLE CAUSES CORRECTIONSQuick Close not working correctly.a) Quick Close setting incorrectb) CLOSE EYE

Page 37

40REPAIR PARTSNOT SHOWN K94-36250 Battery Harness (for 7AH batteries) K94-36531 Wiring Harness with ID Resistor 30 Amp Fuses 1941240D #41 Cha

Page 38

41REPAIR PARTS1234567891011121314151617181920212223

Page 39

42POST-MOUNTING PLATEFor post-mounting model CSL24V commercial slide operator (also SL3000 commercial slide operator). Posts not included.Model MPELRE

Page 40

43MISCELLANEOUSWIRELESS ACCESS CONTROL RECEIVERAccess control receiver for up to 450 remote controls.Model STAR450-315HEATERKeeps operator gearbox and

Page 41

44Field Wiring1Field WiringField WiringCoaxial Antenna CableLNGNDNGNDHeaterTwo 12V Solar Panels in SeriesAccessory Power OutletsAntenna12V 7AH Battery

Page 42 - REPAIR PARTS

45WARRANTY7 YEAR RESIDENTIAL / 5 YEAR COMMERCIAL CSL24V™ AND CSL24VH™ LIMITED WARRANTYThe Chamberlain Group, Inc. (“Seller”) warrants to the first pur

Page 43

01-35593D © 2011, The Chamberlain Group, Inc. – All Rights Reserved845 Larch AvenueElmhurst, Illinois 60126-1196

Page 44 - ACCESSORIES

3 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one com

Page 45

41. GENERAL REQUIREMENTS1.1 Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed, refer to ASTM

Page 46

5InsidePropertyInsideProperty!!To prevent SERIOUS INJURY or DEATH from a moving gate:• Entrapment protection devices MUST be installed to protect an

Page 47 - WARRANTY

6INSTALLATIONTo prevent SERIOUS INJURY or DEATH from a moving gate:• Pinch points must be guarded at all times. Install enclosed-style gate tracks a

Page 48 - Elmhurst, Illinois 60126-1196

7To prevent SERIOUS INJURY or DEATH from a moving gate:• Entrapment protection devices MUST be installed to protect anyone who may come near a movin

Comments to this Manuals