Controlled-products-systems-group 1044682 User Manual Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
Page 21
November, 2003
402 Operator And
455 D Control Panel Installation Manual
THE 455 D CONTROL PANEL INSTALLATION INSTRUCTIONS
ADVANCED PROGRAMMING
+
Display Function De-
fault
M
AXIMUM TORQUE AT INITIAL THRUST:
The motors operate at maximum
torque (ignoring the torque setting)
at start of movement. Useful for
heavy leaves.
4 = Enable
No = Disabled
L
AST STROKE AT CLOSING:
The motors are activated at full
speed for 1s to facilitate locking of
the electric lock.
4 = Enable
No = Disabled
R
EVERSING STROKE:
Before opening, while the gate is
closed, the motors thrust to close
for 2 s thus facilitating release of the
electric lock.
4 = Enable
No = Disabled
L
EAF 2 OPENING DELAY (2S):
Enables delayed start (at opening) of
leaf 2, avoiding interference between
leaves.
4 = Enable
No = Disabled
F
AIL SAFE:
If this function is activated, it en-
ables a function test of the photo-
cells before any gate movement. If
the test fails (photocells not service-
able), the gate does not start the
movement.
4 = Enable
No = Disabled
P
RE FLASHING (5S):
Activates the flashing lamp for 5s
before start of movement.
4 = Enable
No = Disabled
E
LECTRIC LOCK ON LEAF 2:
For using the electric lock on leaf 2
instead of on leaf 1.
4 = Enable
No = Disabled
F
+
Display
Function De-
fault
I
NDICATOR-LICHT:
If 0 is selected, the output functions
as a standard indicator-light (lighted
at opening and pause, flashing at
closing, and off when gate closed).
Different figures correspond to timed
activation of the output, which can be
used (via a relay) to power a courtesy
lamp. Time can be adjusted from 0
to 59s in 1s increments, and from 1.0
to 4.1 min. in 10s steps.
0 = Standard Indicator-Light
From 1 to 4.1 = Timed Output
C
LOSING PHOTOCELLS REVERSE AT RE-
LEASE
: Enable this function if you
want the closing photocells to stop
the gate movement and reverse it
after the beam is cleared. Default set-
ting is immediate reverse.
4 = Enable
No = Disabled
A.D.M.A.P. F
UNCTION:
If this function is enabled, the safety
devices operate in compliance with
French standard NFP 25/362.
4 = Enable
No = Disabled
A
SSISTANCE REQUEST (COMBINED WITH
NEXT FUNCTION): If activated, at the
end of countdown (settable with the
next function, i.e. “Cycle program-
ming”) it effects 8s of pre-flashing at
every Open pulse (job request). Can
be useful for setting scheduled main-
tenance jobs.
4 = Enable
No = Disabled
C
YCLE PROGRAMMING:
For setting count down of system
operation cycles. Settable (in thou-
sands) from 0 to 99 thousand cycles.
The displayed value is updated as
cycles proceed. This function can be
used to check use of the board or to
exploit the “Assistance Request” func-
tion
.
E
XIT PROGRAMMING:
Exit from programming and return to
display of inputs status.
Page view 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 27 28

Comments to this Manuals

No comments