November, 2003
402 Operator And
455 D Control Panel Installation Manual
TECHNICAL DATA
T
HE 402 COMPACT OPERATOR
Parameter 402 Operator
Physical dimensions:
Weight, lb (kg) 14-1/3 (6.5)
Length, in. (mm) 36 (914)
Width ´ height, in. (mm) 3-1/2 ´ 3-1/2 (90 ´ 90)
Motor speed, rpm 1400
90-deg opening time, sec 12
Thrust and traction force, lb (kg) 0–1100
Maximum duty cycle, motor run time 50%
Power voltage required, VAC
(frequency, Hz)
1
115 (50–60)
+
10% or
230, +6 or -10% (50–60)
1
Current draw, amps
115 VAC power source 2.4
220 VAC power source 1.2
Operating temperature range, deg F (deg C)
-4 to 131 (-20 to 55)
Thermal cut out, deg F (deg C) 212 (100)
Oil quantity, qt (liter) 1-1/2 (1.4)
Oil type FAAC XD 220 or Shell/Tellus 15
Gate leaf constraints
Maximum weight per leaf, lb (kg) 900 (410)
Maximum length per leaf, ft (m) 10 (3)
1
Your standard 220 VAC power source meets the specification for
the required power supply of 230 VAC, +6 or –10%.