THE 455 D CONTROL PANEL INSTALLATION INSTRUCTIONS
Page 24
January, 2004
412 Operator And
455 D Control Panel Installation Manual
A (Automatic) Logic (455 D)
Gate Status Open A Open B Stop Opening
Reversing
Device(s)
Closing
Reversing
Device(s)
Warning
Light
Closed
Opens both leaves
and closes them
after pause time
Opens single leaf
connected to Motor
1 and closes it after
pause time
No effect No effect No effect Off
Opening
No effect No effect Stops
Stops; gate closes
when reversing de-
vice no longer trig-
gered
No effect On
Opened
Interrupts the
pause time
Interrupts the
pause time
Stops No effect
Gate remains open
until reversing devices
no longer triggered
On
Closing
Opens both leaves Opens leaf Stops No effect
Depends on DIP
switch 4
Flashes
Stopped
Closes the leaves Closes the leaf
No effect
(opening is
inhibited)
No effect
No effect
(opening is inhibited)
On
Gate Status Open A Open B Stop Opening
Reversing
Device(s)
Closing
Reversing
Device(s)
Warning
Light
Closed
Opens both leaves
and closes them after
pause time
Opens single leaf
connected to Motor
1 and closes it after
pause time
No effect No effect No effect Off
Opening
Closes both leaves Closes leaf Stops
Stops; gate closes
when reversing de-
vice no longer trig-
gered
No effect On
Opened
Closes both leaves Closes leaf Stops No effect
Gate remains open
until reversing devices
no longer triggered
On
Closing
Opens both leave
Opens leaf Stops No effect
Depends on DIP
switch 4
Flashes
Stopped
Closes the leaves Closes the leaf
No effect
(opening is
inhibited)
No effect
No effect (opening is
inhibited)
On
S (Security) Logic (455 D)
Gate Status Open A Open B Stop Opening
Reversing
Device(s)
Closing
Reversing
Device(s)
Warning
Light
Closed
Opens 1 or both
leaves
No effect No effect No effect No effect Off
Opening
No effect No effect Stops No effect Stops On
Opened
No effect
Closes 1 or both
leaves
No effect No effect No effect On
Closing
No effect No effect Stops Stops No effect Flashes
Stopped
Opens 1 or both
leaves
Closes 1 or both
leaves
No effect No effect No effect On
B (Manned, Pulsed) Logic (455 D)